<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Supplier &#124; Distributor &#124; Alat Laboratorium &#124; Teknik Sipil &#124; Pertambangan &#187; Thin-Film Test</title>
	<atom:link href="https://www.rizfapermata.co.id/tag/thin-film-test/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.rizfapermata.co.id</link>
	<description>Supplier, Distributor, Produsen Alat Uji Laboratorium Sipil, Alat Ukur Laboratorium Teknik Sipil, Alat Ukur Pertambangan, Material Testing Equipment for : Soil, Cement, Concrete, Aggregate, Aspal, Alat Preparasi Untuk sample Mineral : Batubara, Nickel, Emas.</description>
	<lastBuildDate>Sat, 06 Feb 2016 02:04:07 +0000</lastBuildDate>
	<language>en-US</language>
		<sy:updatePeriod>hourly</sy:updatePeriod>
		<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=3.9.40</generator>
	<item>
		<title>Loss on Heating, Thin-Film Test</title>
		<link>https://www.rizfapermata.co.id/loss-on-heating-thin-film-test/</link>
		<comments>https://www.rizfapermata.co.id/loss-on-heating-thin-film-test/#comments</comments>
		<pubDate>Fri, 20 Jun 2014 16:28:24 +0000</pubDate>
		<dc:creator><![CDATA[rizfa]]></dc:creator>
				<category><![CDATA[Ashpalt Equipment]]></category>
		<category><![CDATA[Loss on Heating]]></category>
		<category><![CDATA[Thin-Film Test]]></category>

		<guid isPermaLink="false">http://www.rizfapermata.co.id/?p=183</guid>
		<description><![CDATA[Keterangan : BI-220A Loss on Heating/ Thin-Film Test ASTM D-6/ D-1754 AASHTO T-47/ T-179 For determining the loss in mass ( exclusive of water) of asphaltic compounds after heating BI-221 Resolving Shelf Oven Variable temperature oven, cas alumunium rotating shelf, 5-6 RPM, external electromotor drive, 220 V-AC, 1400 Watt. 1 Set GE-390 Thin Box 55 [&#8230;]]]></description>
				<content:encoded><![CDATA[<div id="attachment_184" style="width: 160px" class="wp-caption alignnone"><a href="http://www.rizfapermata.co.id/wp-content/uploads/2014/06/bi-220a.jpg"><img class="size-full wp-image-184" src="http://www.rizfapermata.co.id/wp-content/uploads/2014/06/bi-220a.jpg" alt="Loss on Heating Thin-Film Test" width="150" height="150" /></a><p class="wp-caption-text">Loss on Heating Thin-Film Test</p></div>
<h3 class="p">Keterangan :</h3>
<p>BI-220A Loss on Heating/ Thin-Film Test<br />
ASTM D-6/ D-1754<br />
AASHTO T-47/ T-179</p>
<p>For determining the loss in mass ( exclusive of water) of asphaltic compounds after heating<br />
BI-221 Resolving Shelf Oven Variable temperature oven, cas alumunium rotating shelf, 5-6 RPM, external electromotor drive, 220 V-AC, 1400 Watt. 1 Set<br />
GE-390 Thin Box 55 mm i.d. approx.<br />
alumunium sheet, seamless 12 Pcs<br />
GE-643 Thermometer ASTM 13 C, 155 to 170oC 1 Pc</p>
<p>Also required,<br />
but not part of this set :<br />
CO-473 Ladle<br />
GE-150 Cent O-Gram Balance<br />
GE-222 Butane Field Heater<br />
GE-363 Mixing Bowl<br />
GE-748 Leather Gloves</p>
<p>Dimension ( l x w x h) : 100 x 100 x 100 cm<br />
Gross Weight : 45 kg</p>
]]></content:encoded>
			<wfw:commentRss>https://www.rizfapermata.co.id/loss-on-heating-thin-film-test/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
